Emission series
single driver
stacked ensemble
Meteorological driver
HRRR 3 km
NAM 12 km
GFS 0.25°
What these settings mean
The three weather reconstructions
Nobody recorded the wind everywhere, so the model uses a NOAA computer's hour-by-hour record of it. There are three, and they differ in how sharp the picture is, like the pixels in a photo.
HRRR High-Resolution Rapid Refresh 3 km pixels, the sharpest
NAM North American Mesoscale 12 km pixels, blurrier
GFS Global Forecast System about 25 km pixels, blurriest, whole globe
A sharper picture can see small things, such as a light breeze just above the ground on a calm night. Sharper is not always right. Each one is a best guess, and each gets some nights wrong.
HRRR is the only one that brings the plume to Midtown before dawn on 3 October. It is about six hours late on 6 October.
NAM is the only one with the right timing on 6 October. It misses 3 October.
GFS misses 3 October too, but it explains the chlorine measured at Conyers City Hall on 7 October best.
Press each button and watch the plume go a different way. That disagreement is the main finding.
Single driver or stacked ensemble
This is about how the amount of gas leaving the site is estimated.
Single driver. Trust one weather reconstruction completely and ask how much gas must have left the site to match what the Midtown instrument measured. Each reconstruction gives a different answer, from 11 to 29 tonnes of HNCO.
Stacked ensemble. Ask what one release fits reasonably under all three at once. This gives a single cautious answer, about 12 tonnes.
Think of three friends giving directions to the same house. Single means following one friend exactly: if that friend is right you arrive, and if not you are lost. Stacked means taking only the turns all three roughly agree on. You are less likely to be badly lost, but you match no one friend's route closely.
On the map, stacked looks smoother and single has sharper peaks. With stacked selected, the weather buttons still choose which wind carries that release forward.
Reading the map and the other controls
HNCO. Isocyanic acid, a gas made when pool chemicals burn. It is slow to react away, so it marks where the plume has been.
Colours. Pale yellow is a little gas near the ground and dark red is a lot. No colour means less than 0.3 ppbv.
ppbv. Parts per billion. At 1 ppbv, one molecule in every billion molecules of air is HNCO.
Star and dots. The star is the site that burned. The blue dot is the Georgia Tech instrument in Midtown. The green dot is the second instrument at Conyers City Hall.
Slider, play and speed. Each step is one hour. "5 h/s" plays five hours every second.
Window. Watch the whole period, the days the plume reached Midtown, or the days it stayed near Conyers.
Top chart. How much gas the model has leaving the site each hour.
Bottom chart. Grey bars are what the Midtown instrument measured. The line is what the model predicts there. Where the line sits on the bars, the model is doing well.
ZCTA outlines. Zip code areas. Click one to see its level hour by hour.
Opacity. How see-through the colours are, so you can read the map underneath.
Median fill. For hours that no instrument could pin down, the model uses a typical release rate, not a measured one. The first three days of the fire are entirely filled this way.
Layers
ZCTA outlines (click one for its series)
opacity
Hourly mean HNCO, ppbv
hover the map for a cell value
Selected ZCTA
none selected
About
Passive tracer. Grid cell means, not personal dose. Colours start at 0.3 ppbv. HRRR alone reproduces the 3 Oct dawn arrival at Midtown; NAM alone reproduces 6 Oct; the ensemble series is one emission history that has to satisfy all three drivers at once. Results from archived meteorology under the NOAA HYSPLIT use agreement . Chemical Equity VIP, Georgia Tech.